2013年1月,SAP宣布推出基于SAP HANA的SAP Business Suite。自2012年底SAP宣布推出基于SAP HANA的CRM产品,SAP正式开始将整个Business Suite产品线迁移至HANA平台。继CRM之后,SAP逐渐将ERP、SCM、SRM、PLM等产品线进行迁移,用SAP HANA代替传统数据库。
针对基于SAP HANA的SAP Business Suite,SAP陆续通过了一批硬件认证。从以下配置表中可以看出,与SAP HANA一体机的硬件配置相比,SAP Business Suite on HANA仅有思科、戴尔、富士通、惠普、IBM、NEC六家厂商通过认证,内存容量也达到单机4TB。
支持SAP Business Suite Powered by HANA的一体机配置表:
硬件供应商 | 服务器 | CPU | 存储 | 内存 | 文件系统 | 操作系统 | 限制和注释 |
Cisco | UCS C460 M2 | 4*Westmere EX Intel E7-4870 (2,4 GHz) | Log volume: 1* Fusion-io ioDrive2 1.2 TB, or 2* Fusion-io ioDrive 1.2 TB configured as RAID 1 Data volume: 12* disks 600GB 10k rpm, configured as RAID 5 | 1 TB RAM | ext3, xfs | SLES for SAP 11 SP2 | This configuration is only supported or ERP, CRM and SCM powered by SAP HANA 这一配置仅支持基于SAP HANA的ERP、CRM和SCM |
Dell | R910 | 4*Westmere EX Intel E7-4870 (2,4 GHz) | Log volume : 1* Fusion-io ioDrive2 1.2 TB Data volume: 16 * 600 GB 10k rpm, configured as RAID 6 | 1 TB RAM | ext3 ,xfs | SLES for SAP 11 SP2 | This configuration is only supported for ERP, CRM and SCM powered by SAP HANA 这一配置仅支持基于SAP HANA的ERP、CRM和SCM |
Fujitsu | RX600 S6 | 4*Westmere EX Intel E7-4870 (2,4 GHz) | Log volume: 1* Fusion-io ioDrive2 1.2 TB, or 2* Fusion-io ioDrive 1.2 TB configured as RAID 1 Data volume: 8* 600 GB disks 10k rpm configured as RAID-5 (incl. BBU) | 1 TB RAM | xfs | SLES for SAP 11 SP2 | This configuration is only supported for ERP, CRM and SCM powered by SAP HANA 这一配置仅支持基于SAP HANA的ERP、CRM和SCM |
Fujitsu | RX900 S2 | 8 *Westmere EX Intel E7-8870 (2,4 GHz) | Log volume: 2* Fusion-io ioDrive2 1.2 TB, or 4* Fusion-io ioDrive 1.2 TB configured as RAID 1 Data volume: 18x 900 GB disks 10k rpm configured as RAID-5 (incl. BBU) | 2 TB RAM | xfs | SLES for SAP 11 SP2 | This configuration is only supported for ERP, CRM and SCM powered by SAP HANA 这一配置仅支持基于SAP HANA的ERP、CRM和SCM |
Fujitsu | RX900 S2 | 8 *Westmere EX Intel E7-8870 (2,4 GHz) | Log volume: 4* Fusion-io ioDrive2 1.2 TB configured as RAID 0 Data volume: 24x 900 GB disks 10k rpm configured as RAID-5 (incl. BBU) | 4 TB RAM | xfs | SLES for SAP 11 SP2 | This configuration is only supported for ERP, CRM and SCM powered by SAP HANA 这一配置仅支持基于SAP HANA的ERP、CRM和SCM |
Hitachi | Compute Blade 2000 4 * X57A2 | 8 * Westmere EX Intel E7-8870 2,4 GHz | Log volume: 2*Fusion-io ioDrive 1.2TB (or 4*Fusion-io ioDrive 1.2TB configured as RAID1) Data volume: 30x 300 GB disks 10k rpm configured as RAID-5 over FC on HUS130 | 2 TB RAM | xfs | SLES for SAP 11 SP2 | This configuration is only supported for ERP, CRM and SCM powered by SAP HANA 这一配置仅支持基于SAP HANA的ERP、CRM和SCM |
HP | DL980 G7 | 8 * Westmere EX Intel E7-8870 2,4 GHz | Log volume : 1*Fusion-io ioDrive 2TB (or 2*Fusion-io ioDrive 2TB configured as RAID1) Data volume: 24* 450 GB disks 10k rpm configured as RAID5 | 2 TB RAM | xfs | SLES for SAP 11 SP2 | This configuration is only supported for ERP, CRM and SCM powered by SAP HANA 这一配置仅支持基于SAP HANA的ERP、CRM和SCM |
HP | DL980 G7 | 8 * Westmere EX Intel E7-8870 2,4 GHz | Log volume : 2*Fusion-io ioDrive 2TB configured as RAID0 (or 4*Fusion-io ioDrive 2TB configured as RAID1) Data volume : 50* 450 GB disks 10k rpm configured as RAID5 | 4 TB RAM | xfs | SLES for SAP 11 SP2 | This configuration is only supported for ERP, CRM and SCM powered by SAP HANA 这一配置仅支持基于SAP HANA的ERP、CRM和SCM |
IBM | x3950 X5 or x3850 X5 | 4 *Westmere EX Intel E7-8870 (2,4 GHz) | Log volume : 1* Fusion-io ioDrive2 Mono 1.2TB, using GPFS Data volume: 8* 900GB 10k rpm SAS drives configured as RAID 5 | 1 TB RAM | GPFS | SLES for SAP 11 SP2 | This configuration is only supported for ERP, CRM and SCM powered by SAP HANA 这一配置仅支持基于SAP HANA的ERP、CRM和SCM |
IBM | x3950 X5 or X3850 X5 | 8 *Westmere EX Intel E7-8870 (2,4 GHz) | Log volume: 2* Fusion-io ioDrive2 Mono 1.2TB using GPFS Data volume: 16* 900GB 10k rpm SAS drives configured as 2*RAID 5 | 2 TB RAM | GPFS | SLES for SAP 11 SP2 | This configuration is only supported for ERP, CRM and SCM powered by SAP HANA 这一配置仅支持基于SAP HANA的ERP、CRM和SCM |
IBM | x3950 X5 or X3850 X5 | 8 *Westmere EX Intel E7-8870 (2,4 GHz) | Log volume: 4* Fusion-io ioDrive2 Mono 1.2TB using GPFS Data volume: 24* 900GB 10k rpm SAS drives configured as 2*RAID 5 | 4 TB RAM | GPFS | SLES for SAP 11 SP2 | This configuration is only supported for ERP, CRM and SCM powered by SAP HANA 这一配置仅支持基于SAP HANA的ERP、CRM和SCM |
NEC | Express5800 - A1080a | 8 *Westmere EX Intel E7-8870 (2,4 GHz) | Log volume: 5 * Virident FlashMax 400 GB , configured as RAID 0 Data volume: 12 * 900 GB 10k rpm, configured as (2 * RAID 5) RAID0 | 2 TB RAM | xfs | SLES for SAP 11 SP2 | This configuration is only supported for ERP, CRM and SCM powered by SAP HANA 这一配置仅支持基于SAP HANA的ERP、CRM和SCM |
六、总结
SAP HANA是SAP历史上发展最快的产品,它完成了数据从硬盘到内存的革命,实现了数据处理速度的巨大飞跃。SAP HANA一体机以一种既开放又谨慎的态度,吸引了大批优秀硬件合作伙伴的加入,给SAP HANA带来更多活力和创新。相信通过这篇文章,读者能够进一步了解SAP HANA一体机及其软硬件策略。