技术开发 频道

使用C#开发ActiveX控件

  完成控件开发后,为了使该用户控件作为一个ActiveX控件进行使用,还需要做以下修改:

  首先,为控件类添加GUID,这个编号将用于B/S系统的客户端调用时使用(可以使用 工具-创建GUID 菜单创建一个GUID):

  Guid("4A44CF4E-F859-4328-AA22-3E9D7AFFF1AB")]

  
public partial class Hello : UserControl

 

  其次,为了让ActiveX控件获得客户端的信任,控件类还需要实现一个名为“IObjectSafety”的接口。先创建该接口(注意,不能修改该接口的GUID值):

  using System;

  
using System.Collections.Generic;

  
using System.Text;

  
using System.Runtime.InteropServices;

  
namespace Preresearch.CSharpActiveX

  {

  [ComImport, GuidAttribute(
"CB5BDC81-93C1-11CF-8F20-00805F2CD064")]

  [InterfaceTypeAttribute(ComInterfaceType.InterfaceIsIUnknown)]

  
public interface IObjectSafety

  {

  [PreserveSig]

  
int GetInterfaceSafetyOptions(ref Guid riid, [MarshalAs(UnmanagedType.U4)] ref int pdwSupportedOptions, [MarshalAs(UnmanagedType.U4)] ref int pdwEnabledOptions);

  [PreserveSig()]

  
int SetInterfaceSafetyOptions(ref Guid riid, [MarshalAs(UnmanagedType.U4)] int dwOptionSetMask, [MarshalAs(UnmanagedType.U4)] int dwEnabledOptions);

  }

  }

  然后在控件类中继承并实现该接口:

  
#region IObjectSafety 成员

  
private const string _IID_IDispatch = "{00020400-0000-0000-C000-000000000046}";

  
private const string _IID_IDispatchEx = "{a6ef9860-c720-11d0-9337-00a0c90dcaa9}";

  
private const string _IID_IPersistStorage = "{0000010A-0000-0000-C000-000000000046}";

  
private const string _IID_IPersistStream = "{00000109-0000-0000-C000-000000000046}";

  
private const string _IID_IPersistPropertyBag = "{37D84F60-42CB-11CE-8135-00AA004BB851}";

  
private const int INTERFACESAFE_FOR_UNTRUSTED_CALLER = 0x00000001;

  
private const int INTERFACESAFE_FOR_UNTRUSTED_DATA = 0x00000002;

  
private const int S_OK = 0;

  
private const int E_FAIL = unchecked((int)0x80004005);

  
private const int E_NOINTERFACE = unchecked((int)0x80004002);

  
private bool _fSafeForScripting = true;

  
private bool _fSafeForInitializing = true;

  
public int GetInterfaceSafetyOptions(ref Guid riid, ref int pdwSupportedOptions, ref int pdwEnabledOptions)

  {

  
int Rslt = E_FAIL;

  
string strGUID = riid.ToString("B");

  pdwSupportedOptions
= INTERFACESAFE_FOR_UNTRUSTED_CALLER | INTERFACESAFE_FOR_UNTRUSTED_DATA;

  
switch (strGUID)

  {

  
case _IID_IDispatch:

  
case _IID_IDispatchEx:

  Rslt
= S_OK;

  pdwEnabledOptions
= 0;

  
if (_fSafeForScripting == true)

  pdwEnabledOptions
= INTERFACESAFE_FOR_UNTRUSTED_CALLER;

  
break;

  
case _IID_IPersistStorage:

  
case _IID_IPersistStream:

  
case _IID_IPersistPropertyBag:

  Rslt
= S_OK;

  pdwEnabledOptions
= 0;

  
if (_fSafeForInitializing == true)

  pdwEnabledOptions
= INTERFACESAFE_FOR_UNTRUSTED_DATA;

  
break;

  
default:

  Rslt
= E_NOINTERFACE;

  
break;

  }

  
return Rslt;

  }

  
public int SetInterfaceSafetyOptions(ref Guid riid, int dwOptionSetMask, int dwEnabledOptions)

  {

  
int Rslt = E_FAIL;

  
string strGUID = riid.ToString("B");

  
switch (strGUID)

  {

  
case _IID_IDispatch:

  
case _IID_IDispatchEx:

  
if (((dwEnabledOptions & dwOptionSetMask) == INTERFACESAFE_FOR_UNTRUSTED_CALLER) && (_fSafeForScripting == true))

  Rslt
= S_OK;

  
break;

  
case _IID_IPersistStorage:

  
case _IID_IPersistStream:

  
case _IID_IPersistPropertyBag:

  
if (((dwEnabledOptions & dwOptionSetMask) == INTERFACESAFE_FOR_UNTRUSTED_DATA) && (_fSafeForInitializing == true))

  Rslt
= S_OK;

  
break;

  
default:

  Rslt
= E_NOINTERFACE;

  
break;

  }

  
return Rslt;

  }

  
#endregion

  这样,一个ActiveX控件就开发完成了。

  ActiveX控件部署 ActiveX控件可以使用Visual Studio 2005的安装项目进行部署。这与普通的Windows Form应用程序的部署几乎一样,只有一个地方需要注意,将前面创建的用户控件项目作为主输出项目,并设置其Register属性为vsdrpCOM,如下图所示:

  测试 建立一个Web应用程序项目,在测试页面的HTML代码中添加对ActiveX控件的引用,并且可以通过Javascript调用控件的公共成员(注意这里clsid后面的值即为前面为用户控件类设置的GUID):

  

  将该Web应用程序项目发布到IIS。另外找一台电脑作为客户端测试环境,确保它与服务器端网络连通,安装.NET Framework 2.0和该ActiveX控件。安装完成后,就可以用浏览器访问服务器,进行测试了(你也可以在开发环境的系统中安装该ActiveX控件,并直接在VS 2005中运行WebApp项目查看结果):

  总结

  综上所述,在Visual Studio 2005环境中使用C#开发ActiveX控件,技术实现上没有什么难度,唯一的问题就是客户端需要安装.NET Framework。鉴于ActiveX控件一般都是实现一些简单单一的功能,.NET Framework 2.0已经完全可以应付,所以建议在.NET Framework 2.0下开发。因为相对于.NET Framework 3.5两百多兆的安装包,.NET Framework 2.0安装包只有20多兆,用户相对容易接受一些。

0
相关文章